Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Technol Cancer Res Treat ; 13(2): 129-38, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23862746

RESUMO

The Monaco Treatment Planning System (TPS), based on a virtual energy fluence model of the photon beam head components of the linac and a dose computation engine made with Monte Carlo (MC) algorithm X-Ray Voxel MC (XVMC), has been tested before being put into clinical use. An Elekta Synergy with 6 MV was characterized using routine equipment. After the machine's model was installed, a set of functionality, geometric, dosimetric and data transfer tests were performed. The dosimetric tests included dose calculations in water, heterogeneous phantoms and Intensity Modulated Radiation Therapy (IMRT) verifications. Data transfer tests were run for every imaging device, TPS and the electronic medical record linked to Monaco. Functionality and geometric tests were run properly. Dose calculations in water were in accordance with measurements so that, in 95% of cases, differences were up to 1.9%. Dose calculation in heterogeneous media showed expected results found in the literature. IMRT verification results with an ionization chamber led to dose differences lower than 2.5% for points inside a standard gradient. When an 2-D array was used, all the fields passed the g (3%, 3 mm) test with a percentage of succeeding points between 90% and 95%, of which the majority of the mentioned fields had a percentage of succeeding points between 95% and 100%. Data transfer caused problems that had to be solved by means of changing our workflow. In general, tests led to satisfactory results. Monaco performance complied with published international recommendations and scored highly in the dosimetric ambit. However, the problems detected when the TPS was put to work together with our current equipment showed that this kind of product must be completely commissioned, without neglecting data workflow, before treating the first patient.


Assuntos
Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador , Humanos , Neoplasias/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos
2.
Clin. transl. oncol. (Print) ; 14(11): 853-863, nov. 2012. tab, ilus
Artigo em Inglês | IBECS | ID: ibc-127059

RESUMO

OBJECTIVE: Show that verification through cone beam Kv CT (CBKvCT) in a series of patients treated with 3D external radiotherapy (3DRT) for prostate cancer (PC) is related to a reduction in acute and late toxicity levels. MATERIALS AND METHOD: A retrospective, non-randomized study of two homogeneous groups of patients treated between 2005 and 2008, 46 were verified using electronic portal devices (EPIDs) and 48 through CBKvCT. They received 3DRT for localized PC (T1-T3N0M0) and were prescribed the same doses. Treatment was simulated and planned with the same criteria with the same equipment with a median follow-up time of 24 months (12-54 months). Urinary and gastrointestinal toxicity was determined using Common Toxicity Criteria scale, version 4 and RTOG scales. Statistical analysis of data was performed where p < 0.005 being significative. RESULTS AND DISCUSSION: With an overall median follow-up time of 24 months, the levels of proctitis were, respectively, 19.56, 15.21 and 15.2 % in the first group, compared with 4.17, 2.08 and 8.33 % in the second. Statistically, less total and late proctitis, late rectal bleeding, anal fissure, total and acute haematuria, total and acute urinary frequency and total urinary incontinence was observed. No statistically significant evidence of a lowering in toxicity neither in terms of acute and late dysuria nor of a relationship to the TNM, Gleason or PSA or in the grade of stability. CONCLUSION: Verification through CBKvCT in this series is associated with a statistically significant lowering toxicity. This justifies its use. Greater monitoring would be necessary to assess the impact of verification at the level of biochemical control (AU)


Assuntos
Humanos , Masculino , Tomografia Computadorizada de Feixe Cônico , Proctite/etiologia , Proctite/patologia , Proctite , Lesões por Radiação/etiologia , Lesões por Radiação/patologia , Lesões por Radiação , Radioterapia Guiada por Imagem/efeitos adversos , Bexiga Urinária/patologia , Radioterapia Conformacional , Dosagem Radioterapêutica , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Estudos Retrospectivos
3.
Clin Transl Oncol ; 13(11): 819-25, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22082648

RESUMO

PURPOSE To evaluate the magnitude of systematic and random errors from a subset of 100 prostate and 26 head and neck (H&N) cancer patients treated with conventional conformal radiotherapy and using image-guided radiotherapy (IGRT). After treatment, the uncertainties involved and the CTV to PTV margin were evaluated. MATERIAL AND METHODS An Elekta Synergy® linear accelerator was used, taking advantage of 3D on-board computed tomography. IGRT with no-action level (NAL) protocol was applied, reporting the 3D translation and rotation corrections. A statistical study was performed to analyse systematic, random and interobserver uncertainties, and, finally, to obtain the CTV to PTV margins. RESULTS The H&N patients' uncertainties found were smaller than those of prostate patients. The CTV to PTV margins assessed, following the guidelines found in the literature, in the three dimensions of space (right-left, superior-inferior, anterior-posterior) were (5.3, 3.5, 3.2) mm for H&N and (7.3, 7.0, 9.0) mm for prostate cancer treatments. CONCLUSIONS It was found that assessing all the involved uncertainties within radiation treatments was very revealing; their quality improves using IGRT techniques and performing extensive data analysis.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada de Feixe Cônico , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Masculino , Aceleradores de Partículas , Neoplasias da Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional , Radioterapia Guiada por Imagem/métodos , Incerteza
4.
Clin. transl. oncol. (Print) ; 13(11): 819-825, nov. 2011. tab, ilus
Artigo em Inglês | IBECS | ID: ibc-125944

RESUMO

PURPOSE To evaluate the magnitude of systematic and random errors from a subset of 100 prostate and 26 head and neck (H&N) cancer patients treated with conventional conformal radiotherapy and using image-guided radiotherapy (IGRT). After treatment, the uncertainties involved and the CTV to PTV margin were evaluated. MATERIAL AND METHODS An Elekta Synergy® linear accelerator was used, taking advantage of 3D on-board computed tomography. IGRT with no-action level (NAL) protocol was applied, reporting the 3D translation and rotation corrections. A statistical study was performed to analyse systematic, random and interobserver uncertainties, and, finally, to obtain the CTV to PTV margins. RESULTS The H&N patients' uncertainties found were smaller than those of prostate patients. The CTV to PTV margins assessed, following the guidelines found in the literature, in the three dimensions of space (right-left, superior-inferior, anterior-posterior) were (5.3, 3.5, 3.2) mm for H&N and (7.3, 7.0, 9.0) mm for prostate cancer treatments. CONCLUSIONS It was found that assessing all the involved uncertainties within radiation treatments was very revealing; their quality improves using IGRT techniques and performing extensive data analysis (AU)


Assuntos
Humanos , Masculino , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/complicações , Neoplasias da Próstata/diagnóstico , Tomografia Computadorizada de Feixe Cônico , Neoplasias de Cabeça e Pescoço , Aceleradores de Partículas , Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia Guiada por Imagem/métodos
5.
Clin. transl. oncol. (Print) ; 11(4): 253-256, abr. 2009. tab, ilus
Artigo em Inglês | IBECS | ID: ibc-123611

RESUMO

We present a clinical case of a patient diagnosed with a retroperitoneal sarcoma, which received preoperative treatment with daily verification via computed tomography obtained with kilovoltage cone beam. We compare the benefit of this treatment compared to other conventional treatment without image guiding, reporting quantitative results (AU)


Assuntos
Humanos , Feminino , Adulto , Neoplasias Retroperitoneais/radioterapia , Sarcoma/radioterapia , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada de Feixe Cônico , Neoplasias Retroperitoneais/patologia , Neoplasias Retroperitoneais , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador , Sarcoma/patologia , Sarcoma , Tomografia Computadorizada de Emissão/métodos , Evolução Fatal , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...